Rockwell Automation 284 ArmorStart User Manual User Manual

Page 267

Advertising
background image

Using DeviceLogix™

10-3

7. From the toolbar, Click on the “Discrete Input” button and select

Input 0 from the pull-down menu. This is the remote start button
based on the example I/O table.

8. Place the input to the left of the RSL function. To drop the input

on the page, left click on the desired position.

9. Place the mouse cursor over the tip of Input 0. The tip will turn

green. Click on the tip when it turns green.

10. Move the mouse cursor toward the input of the RSL function. A

line will follow the cursor. When a connection can be made, the
tip of the RSL function will also turn green. Click the on Input
and the line will be drawn from Input 0 to the Set Input of the
RSL function.

Note: If this was not a valid connection, one of the pin tips would

have turned red rather than green. Left double clicking on the
unused portion of the grid or pressing the “Esc” key at any
time will cancel the connection process.

11. From the toolbar, Click on the “Discrete Input” button and select

Input 1 from the pull-down menu. This is the remote stop button
based on the example I/O table.

12. Place the input to the left of the RSL function.

13. Connect the input to the reset input of the RSL latch.

Advertising
This manual is related to the following products: