Rockwell Automation 284 ArmorStart User Manual User Manual

Page 412

Advertising
background image

D-12

Bulletin 284 CIP Information

Table D.32

Logic Command

Power Flex Native Produced Assembly

Instance 171 is the Power Flex Native Format Produced Assembly.

Table D.33 Instance 171 — PowerFlex Native Format Produced Assembly

Accel 2

Accel 1

Description

0

0

No Command

0

1

Accel 1 Enable

1

0

Accel 2 Enable

1

1

Hold Accel Rate Selected

Decel 2

Decel 1

0

0

No Command

0

1

Decel 1 Enable

1

0

Decel 2 Enable

1

1

Hold Decel Rate Selected

Freq Select 3

Freq Select 2

Freq Select 1

0

0

0

No Command

0

0

1

Freq Source = P136 (Start Source)

0

1

0

Freq Source = P169 (Internal Freq)

0

1

1

Freq Source = Comms

1

0

0

P170 (Preset Freq 0)

1

0

1

P171 (Preset Freq 1)

1

1

0

P172 (Preset Freq 2)

1

1

1

P173 (Preset Freq 3)

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

0

Faulted

Alarm

Deceling

Acceling

Rot Fwd

Cmd

Fwd

Running

Ready

1

Drv In 4

Stat

Drv In 3

Stat

Drv In 2 Stat

Drv In 1

Param

Locked

Ctl fm

Net

Ref fm Net At Ref

2

Drive Error Code (low)

3

Drive Error Code (high)