Bulletin 280/281 CIP Information

Connection Object — CLASS CODE
0x0005

No class attributes are supported for the Connection Object

Multiple instances of the Connection Object are supported, instances
1, 2, and 4 from the group 2 predefined master/slave connection set,
instances 5 and 6 are available through explicit UCMM connections.

Instance 1 is the Predefined Group 2 Connection Set Explicit
Message Connection. The following instance 1 attributes is
supported:

Table B.28 Connection Object Instance 1 Attributes

Attribute

ID

Access

Rule

Name

Data
Type

Value

1

Get

State

USINT

0=nonexistant

1=configuring
3=established

4=timed out

2

Get

Instance Type

USINT

0=Explicit

Message

3

Get

Transport Class Trigger

USINT

0x83 — Server,

Transport Class 3

4

Get

Produced Connection ID

UINT

10xxxxxx011

xxxxxx = node

address

5

Get

Consumed Connection ID

UINT

10xxxxxx100

xxxxxx = node

address

6

Get

Initial Comm Characteristics

USINT

0x22

7

Get

Produced Connection Size

UINT

0x61

8

Get

Consumed Connection Size

UINT

0x61

9

Get/Set

Expected Packet Rate

UINT

in ms

12

Get

Watchdog Action

USINT

01 = auto delete

03 = deferred delete

13

Get

Produced Connection Path Length

UINT

0

14

Get

Produced Connection Path

Empty

15

Get

Consumed Connection Path Length

UINT

0

16

Get

Consumed Connection Path

Empty