Rockwell Automation 284 ArmorStart User Manual User Manual
Page 310
Advertising

14-16
Troubleshooting
Control Module Replacement
(Bulletin 283)
Removal of Starter Module
1) Disconnect from power source
2) Remove motor cable.
3) Loosen the four mounting screws.
4) Unplug the Control module from the base by pulling forward.
Installation of Control Module
5) Install control module.
6) Tighten four mounting screws.
7) Install motor cable.
Figure 14.2 Bulletin 283 Control Module Replacement
ATTENTION
!
To avoid shock hazard, disconnect main power
before working on the controller, motor, or control
devices
1
1
2
3
3
4
1
2
Motor Cable
30 lb-in/
3.39 Nm
Note: DeviceNet base module is
shown
Advertising