Removal of Base Module

1) Disconnect from power source.

2) Remove all cables from Starter Module, comunication cables and
all others connected to the inputs and outputs.

3) Loosen four mounting screws on the Control Module.

4) Unplug Control Module from the base by pulling forward.

5) Loosen four mounting screws on the Terminal Access Cover Plate.

6) Remove cover plate.

7) Loosen terminal screws.

8) Remove all wires from terminal block.

9) Remove conduit fittings.

10) Loosen mounting screws and remove.

Figure 14.8 Bulletin 284 Base Module Removal

ATTENTION

!

To avoid shock hazard, disconnect main power
before working on the controller, motor, or control
devices

1

5

6

2

2

8

7

4

3

Base Module