Bulletin 284 Programmable Parameters for Volts per Hertz Controllers

5-25

Zone #3 MAC ID

The node address of the device whose data is to be consumed for zone 3. When set
to the value 64, data consumption is disabled.

Parameter Number

72

Access Rule

GET/SET

Data Type

USINT

Group

ZIP Parameters

Units

Minimum Value

0

Maximum Value

64

Default Value

64

Zone #4 MAC ID

The node address of the device whose data is to be consumed for zone 4. When set
to the value 64, data consumption is disabled.

Parameter Number

73

Access Rule

GET/SET

Data Type

USINT

Group

ZIP Parameters

Units

Minimum Value

0

Maximum Value

64

Default Value

64

Zone #1 Health

Read Only consumed connection status for zone 1

0 = Healthy
1 = Unhealthy

Parameter Number

74

Access Rule

GET

Data Type

BOOL

Group

ZIP Parameters

Units

Minimum Value

0

Maximum Value

1

Default Value

0

Zone #2 Health

Read Only consumed connection status for zone 2

0 = Healthy
1 = Unhealthy

Parameter Number

75

Access Rule

GET

Data Type

BOOL

Group

ZIP Parameters

Units

Minimum Value

0

Maximum Value

1

Default Value

0

Zone #3 Health

Read Only consumed connection status for zone 3

0 = Healthy
1 = Unhealthy

Parameter Number

76

Access Rule

GET

Data Type

BOOL

Group

ZIP Parameters

Units

Minimum Value

0

Maximum Value

1

Default Value

0