Table 8.1

Default Input and Output (I/O) Assemblies

Default Input and Output (I/O)
Assembly Formats

The I/O assembly format for the ArmorStart is identified by the value
in parameter 11 (Consumed IO Assy.) and parameter 12 (Produced IO
Assy.). These values determine the amount and arrangement of the
information communicated to the master scanner. The tables below
identify the default information produced and consumed by the
standard starter. For additional formats and advance configurations
please reference Table B.11 on page B-5.

Table 8.2

Instance 160 — Default Consumed Data for Standard Distributed

Motor Controller (1 byte)

Table 8.3

Instance 161 — Default Produced Data for Standard Distributed

Motor Controller (2 bytes)

Default

Message type

Polled

Consumed data size

1 byte (Rx)

Produced data size

2 bytes (Tx)

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

0

User Out B

User Out A

Not Used

Not Used

Not Used

Fault Reset

Run Rev

Run Fwd

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

0

Not Used

Not Used

Not Used

Ready

Running Rev

Running Fwd

Warning

Tripped

1

Not Used

Not Used

140M On

HOA

Status

User In 3

User In 2

User In 1

User In 0