Bulletin 284 Programmable Parameters for Volts per Hertz Controllers

Comm Loss Time
Sets the time that the drive remain in communication loss before implanting the
option selected in Parameter 205 (Comm Loss Action).

Parameter Number

206

Related Parameters

115, 205

Access Rule

GET/SET

Data Type

UINT

Group

Advanced Program Group

Units

0.1 sec

Minimum Value

0.1 sec

Maximum Value

60.0 sec

Default Value

15.0 sec

Comm Format
This parameter is not available for use with the ArmorStart Distributed Motor
Controller.

Parameter Number

207

Anlg In 0…10V Lo
This parameter is not available for use with the ArmorStart Distributed Motor
Controller.

Parameter Number

210

Anlg In 0…10V HI
This parameter is not available for use with the ArmorStart Distributed Motor
Controller.

Parameter Number

211

Anlg In4…20MA LO
This parameter is not available for use with the ArmorStart Distributed Motor
Controller.

Parameter Number

212

Anlg In4…20 mA HI
This parameter is not available for use with the ArmorStart Distributed Motor
Controller.

Parameter Number

213

Slip Hertz @ FLA
Compensates for the inherent slip in an induction motor. This frequency is added to
the commanded output frequency based on motor current.

Parameter Number

214

Related Parameter

133

Access Rule

GET/SET

Data Type

UINT

Group

Advanced Program Group

Units

0.1 Hz

Minimum Value

0.0 Hz

Maximum Value

10.0 Hz

Default Value

2.0 Hz

Process Time Lo
Scales the time value when the drive is running at Parameter 134 (Minimum Freq).
When set to a value other than zero, Parameter 110 (Process Display) indicates the
duration of the process.

Parameter Number

215

Related Parameters

110, 134

Access Rule

GET/SET

Data Type

UNIT

Group

Advanced Setup

Units

Hz

Minimum Value

0.00

Maximum Value

99.99

Default Value

0.00