O1 monitor configuration, Programming 137 – Yaskawa F7 Drive Programming Manual User Manual

Page 145

Advertising
background image

Programming 137

o1 Monitor Configuration

o1-01 User Monitor Selection

Setting Range:

4 to 45

Factory Default: 6

Setting

Description

4

Control Method

5

Motor Speed

6

Output Voltage (factory default)

7

DC Bus Voltage

8

Output Power

9

Torque Reference

10

Input Terminal Status

11

Output Terminal Status

12

Drive Operation Status

13

Cumulative Operation Time

14

Software Number

15

Terminal A1 Level

16

Terminal A2 Level

17

Terminal A3 Level

18

Motor Secondary Current (I

q

)

19

Motor Excitation Current (I

d

)

20

Output Frequency After Soft Start

21

ASR Input

22

ASR Output

24

PID Feedback Value

25

DI-16H2 Input Status

26

Output Voltage Reference (V

q

)

27

Output Voltage Reference (V

d

)

28

CPU Number

29

Kilowatt-Hours Low 4 Digits

30

Kilowatt-Hours High 5 Digits

32

ACR Output of q Axis

33

ACR Output of q Axis

34

First Parameter Causing an OPE

35

Zero Servo Pulse Count

36

PID Input

37

PID Output

38

PID Setpoint

39

Memobus Communication Error Code

40

Heatsink Cooling Fan Operation Time

44

ASR Output Without Filter

45

Feed Forward Control Output

Advertising