F7 parameter list, Programming 153, Initialization – Yaskawa F7 Drive Programming Manual User Manual

Page 161: User parameters

Advertising
background image

Programming 153

F7 Parameter List

Table A.1 F7 Parameter List

Parameter

No.

Parameter Name

Digital Operator Display

Description

Setting

Range

Factory

Setting

Control Method

V/F

V/F

w/

PG

Open

Loop

Vector

Flux

Vector

Initialization

A1-00

Language Selection
Select Language

Language selection for the Digital Operator.
This parameter is not reset to the factory setting by A1-03.
0: English
1: Japanese
2: Deutsch
3: Francais
4: Italiano
5: Espanol
6: Portugues

0 to 6

0

A

A

A

A

A1-01

Access Level Selection
Access Level

Selects which parameters are accessible via the Digital Operator.
0: Operation Only
1: User Level (only available if A2 parameters have been set)
2: Advanced Level

0 to 2

2

A

A

A

A

A1-02

Control Method Selection
Control Method

Selects the Control Method of the Drive.
0: V/F control without PG
1: V/F control with PG
2: Open Loop Vector
3: Flux Vector (Closed Loop Vector)

0 to 3

2

Q

Q

Q

Q

A1-03

Initialize Parameters
Init Parameters

Used to return all parameters to their factory or user default
settings. (Initializes and then returns A1-03 to zero.)
0: No Initialize
1110: User Initialize (The user must first set their own parameter
values and then store them using parameter o2-03.)
2220: 2-Wire Initialization
3330: 3-Wire Initialization

0 to

3330

0

A

A

A

A

A1-04

Password 1
Enter Password

When the value set into A1-04 does NOT match the value set into
A1-05, parameters A1-01 thru A1-03 and A2-01 thru A2-32 cannot
be changed. All other parameters as determined by A1-01 can be
changed. Parameter A1-05 can be accessed by pressing the MENU
key while holding the RESET key.

0 to

9999

0

A

A

A

A

A1-05

Password 2
Select Password

0 to

9999

0

A

A

A

A

User Parameters

A2-01

User Parameter 1
User Param 1

Selects the parameters to be available in the User Access Level
(A1-01 = 1). These parameters are not related to the User Initialize
function.

b1-01

to

o3-02

A

A

A

A

A2-02

User Parameter 2
User Param 2

A

A

A

A

A2-03

User Parameter 3
User Param 3

A

A

A

A

A2-04

User Parameter 4
User Param 4

A

A

A

A

A2-05

User Parameter 5
User Param 5

A

A

A

A

A2-06

User Parameter 6
User Param 6

A

A

A

A

A2-07

User Parameter 7
User Param 7

A

A

A

A

A2-08

User Parameter 8
User Param 8

A

A

A

A

A2-09

User Parameter 9
User Param 9

A

A

A

A

Denotes that parameter can be changed when the Drive is running.

Advertising