Programming 177, Table a.1 f7 parameter list (continued) – Yaskawa F7 Drive Programming Manual User Manual

Page 185

Advertising
background image

Programming 177

H3-06

Terminal A3 Gain Setting
Terminal A3 Gain

Sets the output level when 10V is input.

0.0 to

1000.0

100.0%

A

A

A

A

H3-07

Terminal A3 Bias Setting
Terminal A3 Bias

Sets the frequency reference when 0V is input.

–100.0

to

+100.0

0.0%

A

A

A

A

H3-08

Terminal A2 Signal Level
Selection
Term A2 Signal

Selects the signal level of terminal A2.

0: 0 to 10Vdc (switch S1-2 must be in the OFF position).
1: -10 to +10Vdc (switch S1-2 must be in the OFF position).
2: 4 to 20mA (switch S1-2 must be in the ON position)

0 to 2

2

A

A

A

A

H3-09

Terminal A2 Function
Selection
Terminal A2 Sel

Selects the function of terminal A2.
Same choices as Terminal A3 Function Selection (H3-05).

0 to 1F

0

A

A

A

A

H3-10

Terminal A2 Gain Setting
Terminal A2 Gain

Sets the output level when 10V is input.

0.0 to

1000.0

100.0%

A

A

A

A

H3-11

Terminal A2 Bias Setting
Terminal A2 Bias

Sets the output level when 0V is input.

–100.0

to

+100.0

0.0%

A

A

A

A

H3-12

Analog Input Filter Time
Constant
Filter Avg Time

This parameter adjusts the filter on all 3 analog inputs. Increase to
add stability, decrease to improve response.

0.00 to

2.00

0.03sec

A

A

A

A

Denotes that parameter can be changed when the Drive is running.

Table A.1 F7 Parameter List (Continued)

Parameter

No.

Parameter Name

Digital Operator Display

Description

Setting

Range

Factory

Setting

Control Method

V/F

V/F

w/

PG

Open

Loop

Vector

Flux

Vector

Advertising