Programming 162, Preset reference, Reference limits – Yaskawa F7 Drive Programming Manual User Manual

Page 170: Table a.1 f7 parameter list (continued)

Advertising
background image

Programming 162

Preset Reference

d1-01

Frequency Reference 1
Reference 1

Setting units are affected by o1-03.

0.00 to

E1-04

Value

0.00Hz

Q

Q

Q

Q

d1-02

Frequency Reference 2
Reference 2

Frequency reference when multi-function input “Multi-step speed
reference 1” is ON. Setting units are affected by o1-03.

0.00Hz

Q

Q

Q

Q

d1-03

Frequency Reference 3
Reference 3

Frequency reference when multi-function input “Multi-step speed
reference 2” is ON. Setting units are affected by o1-03.

0.00Hz

Q

Q

Q

Q

d1-04

Frequency Reference 4
Reference 4

Frequency reference when multi-function input “Multi-step speed
reference 1,2” is ON. Setting units are affected by o1-03.

0.00Hz

Q

Q

Q

Q

d1-05

Frequency Reference 5
Reference 5

Frequency reference when multi-function input “Multi-step speed
reference 3” is ON. Setting units are affected by o1-03.

0.00Hz

A

A

A

A

d1-06

Frequency Reference 6
Reference 6

Frequency reference when multi-function input “Multi-step speed
reference 1,3” is ON. Setting units are affected by o1-03.

0.00Hz

A

A

A

A

d1-07

Frequency Reference 7
Reference 7

Frequency reference when multi-function input “Multi-step speed
reference 2,3” is ON. Setting units are affected by o1-03.

0.00Hz

A

A

A

A

d1-08

Frequency Reference 8
Reference 8

Frequency reference when multi-function input “Multi-step speed
reference 1,2,3” is ON. Setting units are affected by o1-03.

0.00Hz

A

A

A

A

d1-09

Frequency Reference 9
Reference 9

Frequency reference when multi-function input “Multi-step speed
reference 4” is ON. Setting units are affected by o1-03.

0.00Hz

A

A

A

A

d1-10

Frequency Reference 10
Reference 10

Frequency reference when multi-function input “Multi-step speed
reference 1,4” is ON. Setting units are affected by o1-03.

0.00Hz

A

A

A

A

d1-11

Frequency Reference 11
Reference 11

Frequency reference when multi-function input “Multi-step speed
reference 2,4” is ON. Setting units are affected by o1-03.

0.00Hz

A

A

A

A

d1-12

Frequency Reference 12
Reference 12

Frequency reference when multi-function input “Multi-step speed
reference 1,2,4” is ON. Setting units are affected by o1-03.

0.00Hz

A

A

A

A

d1-13

Frequency Reference 13
Reference 13

Frequency reference when multi-function input “Multi-step speed
reference 3,4” is ON. Setting units are affected by o1-03.

0.00Hz

A

A

A

A

d1-14

Frequency Reference 14
Reference 14

Frequency reference when multi-function input “Multi-step speed
reference 1,3,4” is ON. Setting units are affected by o1-03.

0.00Hz

A

A

A

A

d1-15

Frequency Reference 15
Reference 15

Frequency reference when multi-function input “Multi-step speed
reference 2,3,4” is ON. Setting units are affected by o1-03.

0.00Hz

A

A

A

A

d1-16

Frequency Reference 16
Reference 16

Frequency reference when multi-function input “Multi-step speed
reference 1,2,3,4” is ON. Setting units are affected by o1-03.

0.00Hz

A

A

A

A

d1-17

Jog Frequency Reference
Jog Reference

Frequency reference when:
“Jog frequency reference” is selected via multi-function input
terminals. “Jog frequency reference” has priority over “multi-step
speed reference 1 to 4”. d1-17 is also the reference for the JOG key
on the Digital Operator, and the multi-function inputs “forward
jog” and “reverse jog”. Setting units are affected by o1-03.

6.00Hz

Q

Q

Q

Q

Reference Limits

d2-01

Frequency Reference Upper
Limit
Ref Upper Limit

Determines maximum frequency reference, set as a percentage of
maximum output frequency (E1-04). If the frequency reference is
above this value, actual Drive speed will be limited to this value.
This parameter applies to all frequency reference sources.

0.0 to
110.0

100.0%

A

A

A

A

d2-02

Frequency Reference Lower
Limit
Ref Lower Limit

Determines minimum frequency reference, set as a percentage of
maximum output frequency (E1-04). If frequency reference is
below this value, actual Drive speed will be set to this value. This
parameter applies to all frequency reference sources.

0.0 to
110.0

0.0%

A

A

A

A

d2-03

Master Speed Reference
Lower Limit
Ref1 Lower Limit

Determines minimum frequency reference, set as a percentage of
maximum output frequency (E1-04). If frequency reference from
analog input (A1, A2, and A3) is below this value, actual Drive
speed will be set to this value. This parameter applies only to
analog inputs A1, A2, and A3.

0.0 to
110.0

0.0%

A

A

A

A

Denotes that parameter can be changed when the Drive is running.

Table A.1 F7 Parameter List (Continued)

Parameter

No.

Parameter Name

Digital Operator Display

Description

Setting

Range

Factory

Setting

Control Method

V/F

V/F

w/

PG

Open

Loop

Vector

Flux

Vector