Programming 188, Copy function, Auto-tuning – Yaskawa F7 Drive Programming Manual User Manual

Page 196: Table a.1 f7 parameter list (continued)

Advertising
background image

Programming 188

COPY Function

o3-01

Copy Function Selection
Copy Function Sel

This parameter controls the copying of parameters to and from the

Digital Operator.

0: COPY SELECT (no function)

1: INV -> OP READ -

All parameters are copied from the
Drive to the Digital Operator.

2: OP -> INV WRITE -

All parameters are copied from the
Digital Operator to the Drive.

3: OP<-->INV VERIFY - Parameter settings in the Drive are

compared to those in the Digital
Operator.

NOTE: When using the copy function, the Drive model number

(o2-04), software number (U1-14), and control method
(A1-02) must match or an error will occur.

0 to 3

0

A

A

A

A

o3-02

Copy Allowed Selection
Read Allowable

Enables and disables the Digital Operator copy functions.
0: Disabled - No Digital Operator copy functions are allowed.
1: Enabled - Copying allowed.

0 to 1

0

A

A

A

A

Auto-Tuning

T1-00

Motor Selection 1 / 2
Select Motor

Selects which set of motor parameters are to be used and set during
Auto-Tuning. If Motor 2 selection (H1-XX=16) is not selected, this
parameter will not be displayed.
1: 1st Motor - E1 to E2
2: 2nd Motor - E3 to E4

1, 2

1

A

A

A

A

T1-01

Auto-Tuning mode selection
Tuning Mode Sel

Selects the Auto-Tuning mode.
0: Rotational Auto-Tuning (A1-02 = 2 or 3)
1: Stationary Auto-Tuning (A1-02 = 2 or 3)
2: Terminal resistance only, (stationary) Auto-Tuning (A1-

02 = 0, 1, 2, or 3)

0 to 2

0

A

A

A

A

T1-02

Motor Rated Power
Mtr Rated Power

Set the motor rated power in kilowatts (kW).
NOTE:If motor power is given in horsepower, power in kW can be

calculated using the following formula: kW = Hp * 0.746

0.00 to
650.00

kW

Varies

by

kVA

A

A

A

A

T1-03

Motor rated voltage
Rated Voltage

Set the motor rated voltage in Volts (V).

0.0 to
255.0

(240V)

0.0 to
510.0

(480V)

230Vac

or

460Vac

-

-

A

A

T1-04

Motor Rated Current
Rated Current

Set the motor rated current in Amperes (A).

Varies

by

kVA

Varies

by

kVA

A

A

A

A

T1-05

Motor Base Frequency
Rated Frequency

Set the base frequency of the motor in Hertz (Hz).

Varies

by

Duty

Rating*

60.0Hz

-

-

A

A

T1-06

Number of Motor Poles
Number of Poles

Set the number of motor poles.

2 to 48

4 poles

-

-

A

A

T1-07

Motor Base Speed
Rated Speed

Set the base speed of the motor in revolutions per minute (RPM).

0 to

24000

1750

RPM

-

-

A

A

T1-08

Number of PG Pulses
PG Pulses / Rev

Set the number of pulses per revolution (PPR) for the encoder
(pulse generator) being used without any multiplication factor.

0 to

60000

1024

PPR

-

-

-

A

Denotes that parameter can be changed when the Drive is running.

* For Heavy Duty (HD) Rating: Setting Range=0.0 to 300.0. For Normal Duty (ND) Rating: Setting Range=0.0 to 400.0.

Table A.1 F7 Parameter List (Continued)

Parameter

No.

Parameter Name

Digital Operator Display

Description

Setting

Range

Factory

Setting

Control Method

V/F

V/F

w/

PG

Open

Loop

Vector

Flux

Vector

Advertising