Drive Output Specifications

The standard Drive specifications are listed in the following tables.

208-240Vac

Table i.2 208-240Vac Drive Specifications

208-240Vac

208-230Vac

Model Number CIMR-F7U

20P4

20P7 21P5

22P2 23P7 25P5 27P5 2011 2015 2018 2022 2030 2037 2045 2055

2075

2090

2110

Rated output
capacity

(kVA)

1.2

1.6

2.7

3.7

5.7

8.8

12.0 17.0 22.0 27.0 32.0 44.0 55.0

69.0 82.0

110.0

130.0

N/A

Horsepower

*2

0.5/0.75

2

2

3

5

7.5

10

15

20

25

30

40

50

60

75

100

125

Rated output
current

(A)

3.2

4.2

7.0

9.6

15.2 23.0 31.0 45.0 58.0

71

85.0 115.0 145.0 180.0 215

283.0

346.0

Overload capacity

*3

(% of rated output
current for 60 sec.)

150

Current limit (% of
rated output current)

150

Carrier frequency

*4

2kHz

Maximum output
frequency

300.0Hz

Rated output
capacity

(kVA)

1.4

1.8

3.0

4.1

6.4

8.8

12.0 18.0 23.0 29.0 34.0 44.0 62.0

73.0 82.0

120.0

140.0 160.0

Horsepower

*2

0.5/0.75

1

2

3

5

7.5

10

15

20

25

30

40

50/60

75

75

100/125 150

150

Rated output
current

(A)

3.6

4.6

7.8

10.8 16.8 23.0 31.0 46.2 59.4 74.8 88.0 115.0 162.0 192.0 215

312.0

360.0 415.0

Overload capacity

*3

(% of rated output
current for 60 sec.)

107

107

108

107

107

120

120

117

117

114

116

120

107

113

120

109

115

120

Current limit (% of
rated output current)

120

Carrier frequency
(kHz)

*5

10

10

10

8

10

15

15

8

10

10

10

10

5

5

8

2

2

2

Maximum output
frequency

400.0Hz

Maximum output voltage

3-phase; 200, 208, 220, 230, or 240Vac

(Proportional to input voltage)

*1 The difference between Heavy Duty ratings and the Normal Duty ratings for the Drive are the rated input and output current, overload capacity, carrier frequency, current limit, and

maximum output frequency. Parameter C6-01 must be set to value of “0” for Heavy Duty ratings and “2” for Normal Duty ratings. Factory default is Heavy Duty (C6-01=0).

*2 Horsepower ratings are based on 230V or 460V NEC Table 430.150. The maximum applicable motor output is given for a standard 4-pole motor. When selecting the actual motor

and Drive, be sure that the Drive's rated output current is appropriate for the motor's rated current.

*3 Models 2110, 4220, 4300 have an overload rating of 120% of rated output current for 60 seconds.

*4 2kHz is the Maximum carrier frequency value and default carrier frequency value for all models.

*5 Each value shown is the Maximum carrier frequency and default carrier frequency.

O

utpu

t rat

ing

s

Heavy D

uty

*1

Norma

l Duty

*1

Advertising