Programming 59

The Drive has the capability to control 2 motors independently. A second motor may be selected using a multi-function
contact input (H1-0x = 16). This parameter select the control method for motor 2. The control method for motor 1 is selected
via parameter A1-02.

Fig. 39 Two Motor Switching Set-up

The following is a list of parameters that become effective when motor 2 is selected.

E3-08E

E3-02 Motor 2 Maximum Output Frequency

Setting Range:

0.0 to 400.0 Hz

Factory Default: 60.0 Hz

E3-03 Motor 2 Maximum Output Voltage

Setting Range:

0.0 to 255.0V (240V Models)
0.0 to 510.0V (480V Models)

Factory Defaults: 230.0V (240V Models)

480.0V (480V Models)

E3-04 Motor 2 Base Frequency

Setting Range:

0.0 to 400.0 Hz

Factory Default: 60.0 Hz

Table 12 Motor 2 Parameters

V/f Pattern 2

Motor Setup 2

E3-01

Control Method 2

E4-01

Motor Rated FLA

E3-02

Max Frequency

E4-02

Motor Rated Slip

E3-03

Max Voltage

E4-03

No-Load Current

E3-04

Base Frequency

E4-04

Number of Motor Poles

E3-05

Mid Frequency

E4-05

Terminal Resistance

E3-06

Mid Voltage

E4-06

Leakage Inductance

E3-07

Min Frequency

E4-07

Motor Rated Power

E3-08

Min Voltage

-

-

G5

M

M

Motor 1

Motor 2