Programming 70 – Yaskawa F7 Drive Programming Manual User Manual

Page 78

Advertising
background image

Programming 70

The Drive has 6 multi-function contact digital inputs. By programming parameters H1-01 through H1-06, the user can assign specific
functions to each input. Below is a table with a complete list of all of the digital input functions according to control method (A1-02).
Not all functions are available for all control methods. Following the table is a more detailed description of each of the functions.

Table 13 Multi-Function Input Selection

Parameter

Setting

Function

Control Method (A1-02)

V/f

V/f with

PG

Open

Loop

Vector

Flux

Vector

0

3-Wire Control

O

O

O

O

1

Local/Remote Selection

O

O

O

O

2

Option/Inverter Selection

O

O

O

O

3

Multi-Step Frequency Reference 1 (factory default, H1-03)

O

O

O

O

4

Multi-Step Frequency Reference 2 (factory default, H1-04)

O

O

O

O

5

Multi-Step Frequency Reference 3

O

O

O

O

6

Jog Frequency Reference (factory default, H1-05)

O

O

O

O

7

Accel/Decel Time Selection 1

O

O

O

O

8

External Baseblock N.O. (factory default, H1-06)

O

O

O

O

9

External Baseblock N.C.

O

O

O

O

A

Accel/Decel Ramp Hold

O

O

O

O

B

External Overheat Alarm (OH2)

O

O

O

O

C

Terminal A2 Enable

O

O

O

O

D

V/f Control with PG Disabled

X

O

X

X

E

ASR Integral Reset

X

O

X

O

F

Terminal Not Used

O

O

O

O

10

MOP Increase

O

O

O

O

11

MOP Decrease

O

O

O

O

12

Forward Jog

O

O

O

O

13

Reverse Jog

O

O

O

O

14

Fault Reset (factory default, H1-02)

O

O

O

O

15

Fast-Stop N.O.

O

O

O

O

16

Motor 2 Selection

O

O

O

O

17

Fast-Stop N.C.

O

O

O

O

18

Timer Function

O

O

O

O

19

PID Disable

O

O

O

O

1A

Accel/Decel Time Selection 2

O

O

O

O

1B

Program Lockout

O

O

O

O

1C

Trim Control Increase

O

O

O

O

1D

Trim Control Decrease

O

O

O

O

1E

Reference Sample Hold

O

O

O

O

20

External Fault, Normally Open, Always Detected, Ramp To Stop

O

O

O

O

21

External Fault, Normally Closed, Always Detected, Ramp To Stop

O

O

O

O

22

External Fault, Normally Open, During Run, Ramp To Stop

O

O

O

O

23

External Fault, Normally Closed, During Run, Ramp To Stop

O

O

O

O

24

External Fault, Normally Open, Always Detected, Coast to Stop
(factory default, H1-01)

O

O

O

O

25

External Fault, Normally Closed, Always Detected, Coast To Stop

O

O

O

O

26

External Fault, Normally Open, During Run, Coast To Stop

O

O

O

O

27

External Fault, Normally Closed, During Run, Coast To Stop

O

O

O

O

28

External Fault, Normally Open, Always Detected, Fast-Stop

O

O

O

O

29

External Fault, Normally Closed, Always Detected, Fast-Stop

O

O

O

O

2A

External Fault, Normally Open, During Run, Fast-Stop

O

O

O

O

2B

External Fault, Normally Closed, During Run, Fast-Stop

O

O

O

O

2C

External Fault, Normally Open, Always Detected, Alarm Only

O

O

O

O

2D

External Fault, Normally Closed, Always Detected, Alarm Only

O

O

O

O

2E

External Fault, Normally Open, During Run, Alarm Only

O

O

O

O

2F

External Fault, Normally Closed, During Run, Alarm Only

O

O

O

O

30

PID Integral Reset

O

O

O

O

31

PID Integral Hold

O

O

O

O

32

Multi-Step Reference 4

O

O

O

O

34

PID Soft Starter Cancel

O

O

O

O

Advertising