Programming 191 – Yaskawa F7 Drive Programming Manual User Manual

Page 199

Advertising
background image

Programming 191

U1-38

PID Setpoint
PID Setpoint

Setpoint of the PID regulator (PID reference + PID bias).

0.01%

U1-39

Modbus Communication Error
Code
Transmit Err

Modbus serial communication error codes.

-

U1-40

Heatsink Cooling Fan Operation
Time
FAN Elapsed Time

Total operating time of the heatsink cooling fan.

1hr

U1-44

ASR output without filter
ASR out w/o Fil

Output from the speed control loop (ASR) before the ASR
primary delay filter (C5-06). 100% is displayed for rated
secondary current of the motor.

0.01%

U1-45

Feed forward control output
FF Cont Output

Output from feed forward control. 100% is displayed for rated
secondary current of the motor.

0.01%

Table A.2 F7 Monitor List (Continued)

Parameter

No.

Parameter Name

Digital Operator Display

Description

Display Units

1: CRC error
1: Data length error
0: Not used. Always 0.
1: Parity error
1: Overrun error
1: Framing error
1: Timeout
0: Not used. Always 0.

0 0 0 0 0 0 0 0