E2-08 Motor Iron-core Saturation Coefficient 2

Setting Range:

0.50 to 0.75

Factory Default: 0.75

This parameter sets the motor iron saturation coefficient at 75% of the magnetic flux. If the rotational Auto-tuning operation
completes successfully (T1-02 = 0), this value is automatically calculated.

E2-09 Motor Mechanical Loss

Setting Range:

0.0 to 10.0 %

Factory Default: 0.0 %

This parameter sets to the motor mechanical loss as a percentage of motor rated power (kW) capacity. Adjust this setting in the
following circumstances:
· When torque loss is large due to motor bearing friction.
· When the torque loss in the load is large.

E2-10 Motor Iron Loss for Torque Compensation

Setting Range:

0 to 65535 W

Factory Default: Model Dependent

This parameter sets the motor iron loss in watts (W)

E2-11 Motor Rated Output

Setting Range:

0.00 to 650.00 kW

Factory Default: Model Dependent

This parameter sets the motor rated power in kilowatts (kW). If the rotational Auto-tuning operation completes successfully
(T1-02 = 0), this value is automatically calculated.

1 horsepower = 0.746 kilowatts

E2-12 Motor Iron-core Saturation Coefficient 3

Setting Range:

0.0 to 1.60

Factory Default: 1.30

This parameter sets the motor iron saturation coefficient at 130% of the magnetic flux. If the rotational Auto-tuning operation
completes successfully (T1-02 = 0), this value is automatically calculated.

E3 V/F Pattern 2

E3-01 Motor 2 Control Method Selection

Setting

Description

0

V/f Control without PG

1

V/f Control with PG

2

Open Loop Vector (factory default)

3

Flux Vector (Closed Loop Vector)