Programming 159, Accel / decel, S-curve accel/decel – Yaskawa F7 Drive Programming Manual User Manual

Page 167: Table a.1 f7 parameter list (continued)

Advertising
background image

Programming 159

Accel / Decel

C1-01

Acceleration Time 1
Accel Time 1

Sets the time to accelerate from zero to maximum frequency.

0.0

to

6000.0

10.0sec

Q

Q

Q

Q

C1-02

Deceleration Time 1
Decel Time 1

Sets the time to decelerate from maximum frequency to zero.

Q

Q

Q

Q

C1-03

Acceleration Time 2
Accel Time 2

Sets the time to accelerate from zero to maximum frequency when
selected via a multi-function input.

A

A

A

A

C1-04

Deceleration Time 2
Decel Time 2

Sets the time to decelerate from maximum frequency to zero when
selected via a multi-function input.

A

A

A

A

C1-05

Acceleration Time 3
Accel Time 3

Sets the time to accelerate from zero to maximum frequency when
selected via a multi-function input.

A

A

A

A

C1-06

Deceleration Time 3
Decel Time 3

Sets the time to decelerate from maximum frequency to zero when
selected via a multi-function input.

A

A

A

A

C1-07

Acceleration Time 4
Accel Time 4

Sets the time to accelerate from zero to maximum frequency when
selected via a multi-function input.

A

A

A

A

C1-08

Deceleration Time 4
Decel Time 4

Sets the time to decelerate from maximum frequency to zero when
selected via a multi-function input.

A

A

A

A

C1-09

Fast Stop Time
Fast Stop Time

Sets the time to decelerate from maximum frequency to zero for
the multi-function input "Fast Stop" function.

0.0

to

6000.0

10.0sec

A

A

A

A

C1-10

Accel/Decel Time Setting
Unit
Acc/Dec Units

Sets the setting resolution of C1-01 to C1-09
0: 0.01 sec (0.00 to 600.00 sec)
1: 0.1 sec (0.0 to 600.0 sec)

0 to 1

1

A

A

A

A

C1-11

Accel/Decel
Switch Frequency
Acc/Dec SW Freq

Sets the frequency for automatic switching of accel / decel times.
Fout < C1-11: Accel/Decel Time 4
Fout

≥ C1-11: Accel/Decel Time 1

Multi-function inputs "Multi-Acc/Dec 1" and "Multi-Acc/Dec 2"
have priority over C1-11.

Varies

by

Duty

Rating*

0.0Hz

A

A

A

A

S-Curve Accel/Decel

C2-01

S-Curve Characteristic at
Accel Start
SCrv Acc @ Start

0.00 to

2.50

0.20sec

A

A

A

A

C2-02

S-Curve Characteristic at
Accel End
SCrv Acc @ End

0.20sec

A

A

A

A

C2-03

S-Curve Characteristic at
Decel Start
SCrv Dec @ Start

0.20sec

A

A

A

A

C2-04

S-Curve Characteristic at
Decel End
SCrv Dec @ End

0.00sec

A

A

A

A

Denotes that parameter can be changed when the Drive is running.

* For Heavy Duty (HD) Rating: Setting Range=0.0 to 300.0. For Normal Duty (ND) Rating: Setting Range=0.0 to 400.0.

Table A.1 F7 Parameter List (Continued)

Parameter

No.

Parameter Name

Digital Operator Display

Description

Setting

Range

Factory

Setting

Control Method

V/F

V/F

w/

PG

Open

Loop

Vector

Flux

Vector

Time

Run
command

Output frequency

ON

C2-02

C2-01

OFF

S-curve is used to further soften the starting and
stopping ramp. The longer the S-curve time, the
softer the starting and stopping ramp.

C2-03

C2-04

Advertising