PLANET SGSD-1022 User Manual

Page 168

Advertising
background image

User’s Manual of SGSD-1022 / SGSD-1022P

SGSW-2840 / SGSW-2840P


By default, the system automatically detects the speed and duplex mode used on each port, and configures the path cost

according to the values shown below. Path cost “0” is used to indicate auto-configuration mode. When the short path cost

method is selected and the default path cost recommended by the IEEE 8021w standard exceeds 65,535, the default is set to

65,535.

Port Type

IEEE 802.1D-1998

IEEE 802.1w-2001

Ethernet

50-600

200,000-20,000,000

Fast Ethernet

10-60

20,000-2,000,000

Gigabit Ethernet

3-10

2,000-200,000

Table 4-7-1 Recommended STA Path Cost Range

Port Type

Link Type

IEEE 802.1D-1998

IEEE 802.1w-2001

Ethernet

Half Duplex

Full Duplex

Trunk

100

95

90

2,000,000

1,999,999

1,000,000

Fast Ethernet

Half Duplex

Full Duplex

Trunk

19

18

15

200,000

100,000

50,000

Gigabit Ethernet

Full Duplex

Trunk

4

3

10,000

5,000

Table 4-7-2 Recommended STA Path Costs

Refer to “

Configuring Global Settings

” for information on setting the path cost method.

Port Type

Link Type

IEEE 802.1w-2001

Ethernet

Half Duplex

Full Duplex

Trunk

2,000,000

1,000,000

500,000

Fast Ethernet

Half Duplex

Full Duplex

Trunk

200,000

100,000

50,000

Gigabit Ethernet

Full Duplex

Trunk

10,000

5,000

Table 4-7-3 Default STA Path Costs

168

Advertising