4.2.8 Log

The switch allows you to control the logging of error messages, including the type of events that are recorded in switch memory,

logging to a remote System Log (syslog) server, and displays a list of recent event messages. This section has the following

options:

System Logs

Sends error messages to a logging process

Remote Logs

Configures the logging of messages to a remote logging process

SMTP

Sends an SMTP client message to a participating server.

Logs

Stores and displays error messages

4.2.8.1 System Log Configuration

The system can be configured to send debug and error messages to a logging process. This logging process controls the type

of error messages that are stored in switch memory or sent to a remote syslog server.

The system allows you to enable or disable event logging, and specify which levels are logged to RAM or flash memory.

Severe error messages that are logged to flash memory are permanently stored in the switch to assist in troubleshooting

network problems. Up to 4096 log entries can be stored in the flash memory, with the oldest entries being overwritten first when

the available log memory (256 kilobytes) has been exceeded.

The System Logs page allows you to configure and limit system messages that are logged to flash or RAM memory. The default

is for event levels 0 to 3 to be logged to flash and levels 0 to 6 to be logged to RAM.

The following table lists the event levels of the Managed Switch:

Level

Severity Name

Description

7

Debug

Debugging messages

6

Informational

Informational messages only

5

Notice

Normal but significant condition, such as cold start

4

Warning

Warning conditions (e.g., return false, unexpected return)

3

Error

Error conditions (e.g., invalid input, default used)

2

Critical

Critical conditions (e.g., memory allocation, or free memory

error - resource exhausted)

1

Alert

Immediate action needed

0

Emergency

System unusable