Snmp-server enable traps – PLANET SGSD-1022 User Manual

Page 419

Advertising
background image

User’s Manual of SGSD-1022 / SGSD-1022P

SGSW-2840 / SGSW-2840P

Console(config)#snmp-server host 10.1.19.23 batman

Console(config)#

Related Commands

snmp-server enable traps

snmp-server enable traps

This command enables this device to send Simple Network Management Protocol traps or informs (i.e., SNMP notifications).

Use the no form to disable SNMP notifications.

Syntax

[no] snmp-server enable traps [authentication | link-up-down]

authentication - Keyword to issue authentication failure notifications.

link-up-down - Keyword to issue link-up or link-down notifications.

Default Setting

Issue authentication and link-up-down traps.

Command Mode

Global Configuration

Command Usage

If you do not enter an snmp-server enable traps command, no notifications controlled by this command are sent. In order

to configure this device to send SNMP notifications, you must enter at least one snmp-server enable traps command. If

you enter the command with no keywords, both authentication and link-up-down notifications are enabled. If you enter the

command with a keyword, only the notification type related to that keyword is enabled.

The snmp-server enable traps command is used in conjunction with the snmp-server host command. Use the

snmp-server host command to specify which host or hosts receive SNMP notifications. In order to send notifications, you

must configure at least one snmp-server host command.

The authentication, link-up, and link-down traps are legacy notifications, and therefore when used for SNMP Version 3

hosts, they must be enabled in conjunction with the corresponding entries in the Notify View assigned by the snmp-server

group command (page 4-79).

Example

Console(config)#snmp-server enable traps link-up-down

Console(config)#

Related Commands

snmp-server host

419

Advertising
This manual is related to the following products: