4.2.8.2 Remote Log Configuration

The Remote Logs page allows you to configure the logging of messages that are sent to syslog servers or other management

stations. You can also limit the event messages sent to only those messages below a specified level.

Figure 4-2-18 Remote Logs screenshot

1. Click System, Log, Remote Logs.

2. To add an IP address to the Host IP List, type the new IP address in the Host IP Address box, and then click Add.

3. To delete an IP address, click the entry in the Host IP List, and then click Remove.

The page includes the following fields:

Object

Description

Remote Log Status

Enables/disables the logging of debug or error messages to the remote logging

process.

(Default: Enabled)

Logging Facility

Sets the facility type for remote logging of syslog messages. There are eight

facility types specified by values of 16 to 23. The facility type is used by the

syslog server to dispatch log messages to an appropriate service.

The attribute specifies the facility type tag sent in syslog messages. (See RFC

3164.) This type has no effect on the kind of messages reported by the switch.

However, it may be used by the syslog server to process messages, such as

sorting or storing messages in the corresponding database.