Snmp-server host – PLANET SGSD-1022 User Manual

Page 417

Advertising
background image

User’s Manual of SGSD-1022 / SGSD-1022P

SGSW-2840 / SGSW-2840P


Console(config)#snmp-server location WC-19

Console(config)#

Related Commands

snmp-server contact

snmp-server host

This command specifies the recipient of a Simple Network Management Protocol notification operation. Use the no form to

remove the specified host.

Syntax

snmp-server host host-addr [inform [retry retries | timeout seconds]] community-string [version {1 | 2c | 3 {auth | noauth |

priv} [udp-port port]} no snmp-server host host-addr

host-addr - Internet address of the host (the targeted recipient). (Maximum host addresses: 5 trap destination IP address

entries) inform - Notifications are sent as inform messages.

Note that this option is only available for version 2c and 3 hosts. (Default: traps are used) -retries - The maximum number

of times to resend an inform message if the recipient does not acknowledge receipt. (Range: 0-255; Default: 3)

-seonds - The number of seconds to wait for an acknowledgment before resending an inform message. (Range:

0-2147483647 centiseconds; Default: 1500 centiseconds)

community-string -Password-like community string sent with the notification operation to SNMP V1 and V2c hosts.

Although you can set this string using the snmp-server host command by itself, we recommend that you define this string

using the snmp-server community command prior to using the snmp-server host command. (Maximum length: 32

characters)

•version - Specifies whether to send notifications as SNMP Version 1, 2c or 3 traps. (Range: 1, 2c, 3; Default: 1) -auth |

noauth | priv - This group uses SNMPv3 with authentication, no

authentication, or with authentication and privacy. See “Simple Network Management Protocol” on page 3-39 for further

information about these authentication and encryption options.

port - Host UDP port to use. (Range: 1-65535; Default: 162)

Default Setting

Host Address: None

Notification Type: Traps

SNMP Version: 1

UDP Port: 162

Command Mode

Global Configuration

Command Usage

If you do not enter an snmp-server host command, no notifications are sent. In order to configure the switch to send