Silent-time, Databits – PLANET SGSD-1022 User Manual

Page 389

Advertising
background image

User’s Manual of SGSD-1022 / SGSD-1022P

SGSW-2840 / SGSW-2840P

Command Mode

Line Configuration

Command Usage

When the logon attempt threshold is reached, the system interface becomes silent for a specified amount of time before

allowing the next logon attempt. (Use the silent-time command to set this interval.) When this threshold is reached for

Telnet, the Telnet logon interface shuts down.

This command applies to both the local console and Telnet connections.

Example

To set the password threshold to five attempts, enter this command:

Console(config-line)#password-thresh 5

Console(config-line)#

Related Commands

silent-time

timeout login response

silent-time

This command sets the amount of time the management console is inaccessible after the number of unsuccessful logon

attempts exceeds the threshold set by the password-thresh command. Use the no form to remove the silent time value.

Syntax

silent-time [seconds]

no silent-time

seconds -The number of seconds to disable console response.

(Range: 0-65535; 0: no silent-time)

Default Setting

The default value is no silent-time.

Command Mode

Line Configuration

Example

To set the silent time to 60 seconds, enter this command:

Console(config-line)#silent-time 60

Console(config-line)#

Related Commands

password-thresh

databits

This command sets the number of data bits per character that are interpreted and generated by the console port. Use the no