Input strings cannot contain spaces. The banner configure dc-power-info command interprets spaces as data input

boundaries.

The use of underscores ( _ ) or other unobtrusive non-letter characters is suggested for situations where whitespace is

necessary for clarity.

Example

Console(config)#banner configure floor 3 row 15 rack 24

electrical-circuit 48v-id_3.15.24.2

Console(config)#

banner configure department

This command is used to configure the department information displayed in the banner. Use the no form to restore the default

setting.

Syntax

banner configure department dept-name no banner configure company dept-name -The name of the department.

(Maximum length: 32 characters)

Default Setting

None

Command Mode

Global Configuration

Command Usage

Input strings cannot contain spaces. The banner configure department command interprets spaces as data input

boundaries. The use of underscores ( _ ) or other unobtrusive non-letter characters is suggested for situations where

whitespace is necessary for clarity.

Example

Console(config)#banner configure department R&D

Console(config)#

banner configure equipment-info

This command is used to configure the equipment information displayed in the banner. Use the no form to restore the default

setting.