Garp timer – PLANET SGSD-1022 User Manual

Page 570

Advertising
background image

User’s Manual of SGSD-1022 / SGSD-1022P

SGSW-2840 / SGSW-2840P

GVRP configuration: Enabled

Console#

garp timer

This command sets the values for the join, leave and leaveall timers. Use the no form to restore the timers’ default values.

Syntax

garp timer {join | leave | leaveall} timer_value

no garp timer {join | leave | leaveall}

{join | leave | leaveall} - Which timer to set.

timer_value - Value of timer.

Ranges:

join: 20-1000 centiseconds

leave: 60-3000 centiseconds

leaveall: 500-18000 centiseconds

Default Setting

join: 20 centiseconds

leave: 60 centiseconds

leaveall: 1000 centiseconds

Command Mode

Interface Configuration (Ethernet, Port Channel)

Command Usage

Group Address Registration Protocol is used by GVRP and GMRP to register or deregister client attributes for client

services within a bridged LAN. The default values for the GARP timers are independent of the media access method or

data rate. These values should not be changed unless you are experiencing difficulties with GMRP or GVRP

registration/deregistration.

Timer values are applied to GVRP for all the ports on all VLANs.

Timer values must meet the following restrictions:

-leave >= (2 x join)

-leaveall > leave

Set GVRP timers on all Layer 2 devices connected in the same network to the same values.

Otherwise, GVRP may not operate successfully.