7.5 Commands and Execution Scans

7-17

7

Programming

7.5 Commands and Execution Scans

7.5.1 Command Types

There are three motion language command types. The number of scans required to execute a command will differ
depending on the command type. The following table shows the number of scans required to execute each type of
command.

The details of each command type follow:

• S Type Commands

S type commands, including operation commands, are executed in one scan.
A program in which S type commands are continuously coded is executed within one scan.

• M Type Commands

M type commands, including axis move commands, are executed in more than one scan.
One scan is required to switch from the S type command to the M type command.

• T Type Commands

T type commands, including timer related commands, are executed in more than one scan.

The following diagram shows the number of scans required to execute each command type.

Command Type

Command

Number of Scans Required

to Execute a Command

S type

Operation commands

One scan

M type

Axis move commands

More than one scan

T type

Timer related commands

S type command

S type command

S type command

T type command

END;

Executed in one scan

Executed in more

than one scan

Waits for one scan

Executed in more

than one scan

M type command

M type command

S type command

S type command

S type command

Executed in one scan

When the command before an S type command is

an M type, the S type command is executed at

the last scan of the M type command.

Advertising