8 Command Reference

8.2.1 Positioning (MOV)

8-48

(a) No acceleration/deceleration

Movement with both the acceleration time and deceleration time set to 0

(b) Single-step linear acceleration/deceleration

Movement with a constant acceleration/deceleration speed

(c) S-curve acceleration/deceleration

Movement at S-curved acceleration/deceleration speed

For axis movement with a MOV command, an in-position check is executed to verify that the axis enters the positioning
completion range. After the in-position check, the next move command block will be executed.
The following diagram illustrates the in-position execution.

Fig. 8.25 Execution of In-position Check

Setting Method

Movement Path

• OW

03, bit 4 to 7: Acceleration/deceleration degree unit selection = 1

(ms)

• OW

03, bit 8 to B: Filter type selection = 0 (No filter)

• Set the ACC command to 0.
• Set the DCC command to 0.

Setting Method

Movement Path

• OW

03, bit 4 to 7: Acceleration/deceleration degree unit selection = 1

(ms)

• OW

03, bit 8 to B: Filter type selection = 0 (No filter)

• Set the ACC command to a value other than 0.
• Set the DCC command to a value other than 0.

Setting Method

Movement Path

• OW

03, bit 4 to 7: Acceleration/deceleration degree unit selection = 1

(ms)

• OW

03, bit 8 to B: Filter type selection = 2 (Moving average filter)

• Set the ACC command to a value other than 0.
• Set the DCC command to a value other than 0.
• Set the SCC command to a value other than 0.

INFO

Positioning command block

The next command block

In-position check

Motion monitor parameter

IW

0C, Bit1 Positioning Completed

The value that is set in the motion setting parameter

OL

1E: Width of positioning completion.

Distribution completed

Speed (V)

Time (t)

The feedback position is within

the positioning completion width.

Advertising