8 Command Reference

8.2.4 Clockwise/Counterclockwise Circular Interpolation with Radius Designation (MCW, MCC)

8-62

(2) Format

(3) Setting Items for MCW and MCC Commands

Motion Image

a) Radius

Specify a numerical value or register following to character R in the MCW or MCC command block.
The circular interpolation path will differ depending on the radius reference value as follows.

With the MCW command block MCW [A1]

− [B1] − R −;

If R

>

0: Circular interpolation with an arc angle of 180

°

or less

If R

<

0: Circular interpolation with an arc angle of more than 180

°

If R = 0: A motion program alarm will occur.

With the radius designating circular interpolation, the number of turns cannot be specified.

Notes: 1. The interpolation feed speed can be omitted.

Item

Unit

Usable Data

End position

Reference unit

Radius

Reference unit

Interpolation feed speed Reference units/min

Directly designated value
Double integer type register (Indirect designation)

MCW [Logical axis name 1] End position [Logical axis name 2] End position R Radius F Interpolation speed ;

2. With radius designating circular interpolation, the number of turns cannot be specified.

Logical axis 2

Logical axis 1

a) Radius

End position

MCW

More than 180°

180° max.

Center point

when R is a

positive value

Center

point when

R is a negative

value

R

Program current position

End position

R

INFO