Yaskawa MP2000 Series: User's Manual for Motion Programming User Manual

Page 319

Advertising
background image

10 Troubleshooting

10.2.4 Motion Program Alarm Codes

10-16

1Fh

Address P out of range

Designation exceeded the valid range in the
IFP command.

Review the setting in the IFP command.

21h

PFORK execution
error

A motion command was instructed simulta-
neously at the second line in the PFORK of
both a source motion program and a subpro-
gram.

Review the source motion program or
subprogram.

22h

Indirect register range
error

Specified register address exceeds the regis-
ter size range.

Review the motion program.

23h

Moving amount out of
range

Axis moving amount with decimal point for
an axis move command exceeded the possi-
ble range.

Review the axis moving amount.

80h

Use of logical axis
prohibited

Multiple motion commands instructed
against the same axis at the same time.

Review the motion program.

81h

Designation exceeded
POSMAX in the infi-
nite length axis

Moving distance designation exceeded
POSMAX in the infinite length axis.

• Modify the fixed parameter “Maxi-

mum infinite length axis counter”

• Review the motion program.

82h

Axis moving distance
exceeded
LONG_MAX

Axis moving distance designation exceeded
the valid range.

Review the motion program.

84h

Duplicated motion
command

Multiple commands ware executed against
a single axis.

Check to see whether another program
gave a command to the same axis at the
same time. If so, review the program.

85h

Motion command
response error

A motion command response different from
that instructed by the motion command is
reported from a motion module.

• Remove the alarm cause from the des-

tination axis.

• If the servo is not turned ON, turn ON

the servo.

• Check to see whether another program

gave a command to the same axis at
the same time. If so, review the pro-
gram.

87h

VEL setting data out
of range

An instruction in the VEL command
exceeded the valid range.

Review the VEL command.

88h

INP setting data out of
range

An instruction in the INP command
exceeded the valid range.

Review the INP command.

89h

ACC/SCC/DCC set-
ting data out of range

An instruction in the ACC/SCC/DCC com-
mand exceeded the valid range.

Review the ACC/SCC/DCC command.

8Ah

No time specified in
the MVT command

T designation in the MVT command was
zero.

Review the MVT command.

8Bh

Command execution
disabled

A motion command which cannot be exe-
cuted by the destination motion module was
instructed.

Review the motion program.

8Ch

Distribution
incomplete

A motion command was executed when a
motion module was not in the Distribution
Completed state.

Review the motion program so that the
motion command is executed in the Dis-
tribution Completed state.

8Dh

Motion command
abnormally aborted

Motion module fell into the “Motion com-
mand abnormally aborted” state.

• Release the destination axis error.
• Review the motion program.

Alarm

Code

Name

Description

Corrective Actions

Advertising