Important – Yaskawa MP2000 Series: User's Manual for Motion Programming User Manual

Page 165

Advertising
background image

8 Command Reference

8.2.3 Clockwise/Counterclockwise Circular Interpolation with Center Position Designation (MCW, MCC)

8-58

Special care must be taken with regard to the start point radius, and end point radius, because the circular inter-
polation path will become as shown below if the start point radius is not equal to the end point radius.

Fig. 8.30 Circular Interpolation Path When Start Point Radius

≠ End Point Radius

b) Number of turns

Specify a numerical value or register following to character T in the MCW or MCC command block.
Specifying the number of turns will implement multiple circular movements. Specifying a negative value for
the number of turns will cause a motion program alarm. The number of circular movements determined by
the specified number of turns will differ depending on the relationship between the program current position
and end position as shown below.

• When the number of turns is set to 2

IMPORTANT

Start point

radius

End point ratius

Center

position

Program

current position

End position

EXAMPLE

B1

A1

Two circles + 1/4 circle

Program

current position

End position

When Program current position ≠ End position

B1

A1

Three circles

Program current position

and

End position

Program current position = End position

Advertising