6 Variables (Registers)

6.2.4 Output Variables (O Registers)

6-12

The register numbers for each axis of motion setting parameters can be obtained by the following equation.

The register start number of the motion setting parameter
= OW8000 + (Circuit No. -1) × 800h + (Axis No. -1) × 80h

(3) Programming Examples

The output data and motion setting parameters are written in.

• Bit Designation

• Integer Designation

• Double Integer Designation

Table 6.6 Register Numbers of Motion Parameter

Axis No.

Circuit No.

Axis 1

Axis 2

Axis 3

Axis 4

Axis 5

• •

Axis 16

1

8000 to 807F

8080 to 80FF

8100 to 817F

8180 to 81FF

8200 to 827F

• •

8780 to 87FF

2

8800 to 887F

8880 to 88FF

8900 to 897F

8980 to 89FF

8A00 to 8A7F

• •

8F80 to 8FFF

3

9000 to 907F

9080 to 90FF

9100 to 917F

9180 to 91FF

9200 to 9A7F

• •

9780 to 97FF

4

9800 to 987F

9880 to 98FF

9900 to 997F

9980 to 99FF

9A00 to 997F

• •

9F80 to 9FFF

5

A000 to A07F

A080 to A0FF

A100 to A17F

A180 to A1FF

A200 to A27F

• •

A780 to A7FF

6

A800 to A87F

A880 to A8FF

A800 to A87F

A980 to A9FF

AA00 to AA7F

• •

AF80 to AFFF

7

B000 to B07F

B080 to B0FF

B100 to B17F

B180 to B1FF

B200 to B27F

• •

B780 to B7FF

8

B800 to B87F

B880 to B8FF

B900 to B97F

B980 to B9FF

BA00 to BA7F

• •

BF80 to BFFF

9

C000 to C07F

C080 to C0FF

C100 to C17F

C180 to C1FF

C200 to C27F

• •

C780 to C7FF

10

C800 to C87F

C880 to C8FF

C900 to C97F

C980 to C9FF

CA00 to CA7F

• •

CF80 to CFFF

11

D000 to D07F

D080 to D0FF

D100 to D17F

D180 to D1FF

D200 to D27F

• •

D780 to D7FF

12

D800 to D87F

D880 to D8FF

D900 to D97F

D980 to D9FF

DA00 to DA7F

• •

DF80 to DFFF

13

E000 to E07F

E080 to E0FF

E100 to E17F

E180 to E1FF

E200 to E27F

• •

E780 to E7FF

14

E800 to E87F

E880 to E8FF

E900 to E97F

E980 to E9FF

EA00 to A97F

• •

EF80 to EFFF

15

F000 to F07F

F080 to F0FF

F100 to F17F

F180 to F1FF

F200 to F27F

• •

F780 to EFFF

16

F800 to F87F

F880 to F8FF

F900 to F97F

F980 to F9FF

F900 to F97F

• •

FF80 to FFFF

Module number offset

INFO

OB01000=MB001000 & IB00100;

OW8008=MW00100;

OL8010=ML00100+ML00200;

EXAMPLE

Advertising