8.9 Basic Functions
8-155
8
Command Reference
(3) Programming Examples
TON command programming examples are shown below.
• Ladder equivalent circuit
• Timing chart
DB000001=DB000000 & TON (500 DW00001);
↑ Set to 5 seconds.
EXAMPLE
DB000000
DB000001
500
DW00001
5.00 s Ts
㧔
Ts = Scan set value㧕