9.7 Test Run Function

9-29

9

Engineering T

ool

MPE720

9.7.2 Test Run Window Details

a) Axis

Select the axis for the test run.

b) Servo Enable, Alarm

The servo status (Enabled [servo ON] or Disabled) [servo OFF] and the axis alarm status (Alarm or No
Alarm
) are displayed.

c) Enable, Disable, and Monitor buttons

Click the Enable button to turn ON the servo, click the Disable button to turn it OFF. Special care must be
taken for this operation because it will change the motion setting parameter.
Click the Monitor button to display the details of an axis alarm.

Switch by clicking the Jog or Step tab.