3) program alarm bit of status flag, 6 (3) program alarm bit of status flag – Yaskawa MP2000 Series: User's Manual for Motion Programming User Manual

Page 309

Advertising
background image

10 Troubleshooting

10.2.2 Problem Starting a Motion Program

10-6

(3) Program Alarm Bit of Status Flag

If status flag bit 8 (Program alarm) is ON, the motion program is disabled from running because of the alarm in
the motion program.
Remove the cause of the alarm by referring to 10.2.4 Motion Program Alarm Codes, and then turn ON motion
program control signal bit 5 (Program reset and alarm reset request) to reset the alarm. After the alarm is reset,
start the motion program again.

Status flag

Motion program

work register

Control signal

Interpolation override

System work number

1st word

Control signal, bit 0:

Program operation start request

Program running

Bit 0

Program reset and alarm

reset request bit ON

2nd word
3rd word
4th word

Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9

Bit A
Bit B
Bit C
Bit D
Bit E
Bit F

Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9

Bit A
Bit B
Bit C
Bit D
Bit E
Bit F

Program running
Program paused
Stopped by program stop request
(Reserved by the system)
Program single-block operation stopped
(Reserved by the system)
(Reserved by the system)
(Reserved by the system)
Program alarm
Stopped by break point
(Reserved by the system)
In debug mode
Program type
Start request signal history
“No system work” error, Execution scan error
Main program No. outside the range

Program operation start request
Program pause request
Program stop request
Program single-block mode selection
Program single-block operation start request
Program reset and alarm reset request
Program continuous operation start request
(Reserved by the system)
Skip 1 information
Skip 2 information
(Reserved by the system)
(Reserved by the system)
(Reserved by the system)
System work number setting
Interpolation override setting
(Reserved by the system)

Program reset and alarm

reset request

Status flag, bit 8:

Program alarm occurring

An alarm occurred in the

motion program.

Alarm reset

The motion program will not start while

an alarm is occurring even when the

program start request bit is turned ON.

The motion program starts

running when the program start

request bit is turned ON.

Status flag bit 8 turns

OFF when the Program

reset and alarm reset

request bit turns ON.

The motion program cannot start

when this bit is ON because an

alarm is occurring in the motion

program.

When this bit turns ON, the motion

program alarm is reset.

Status flag, bit 0:

Control signal, bit 5:

Advertising