8 Command Reference

8.1.8 Interpolation Feed Speed Ratio Setting (IFP)

8-38

(2) Format

IFP command cannot be coded in the same block used for an interpolation command MVS, MCW, MCC, or SKP.

(3) Setting Items for IFP Command

Motion Image

a) Interpolation feed speed ratio

Specify a numerical value or register following to character P in the IFP command block.
The IFP command sets a percentage of the maximum interpolation feed speed (FMX) as the interpolation
feed speed.
The interpolation feed speed is a composite speed of all the axes specified for an interpolation related com-
mand MVS, MCW, MCC, or SKP.
The interpolation feed speed ratio reference range is as follows.

You can select whether or not to apply an interpolation override to the interpolation feed speed.
Refer to 4.3.3 Work Registers for information on how to use the interpolation override.

• When not using an interpolation override

IFP

P

Interpolation feed speed ratio;

Item

Unit

Usable Data

Interpolation

feed speed

ratio

%

Directly designated value

Double integer type register (Indirect designation)

INFO

1 to 100 (%)

Speed (V)

[%]

Time (t)

100

Max. feed speed

for interpolation

(FMX)

(Composite speed)

a) Interpolation feed

speed ratio

(IFP)

Interpolation

acceleration time

(IAC)

Interpolation

deceleration time

(IDC)

FMX reference value ×

IFP reference value

1 to 100%

=

Interpolation feed speed

Interpolation

feed speed

FMX

reference value

IFP

reference value

Advertising