A.9 Basic Functions

A-10

A.9 Basic Functions

Com-
mand

Name

Programming Format

Description

Mo

tion Programs

Seq

uen

ce

Prog

rams

SIN

Sine

SIN (MW

− );

SIN (90) ;

Obtains the sine of integer or real number data.
The specifications differ depending on the data
type: Integer or real number.

COS

Cosine

COS (MW

− );

COS (90) ;

Obtains the cosine of integer or real number data.
The specifications differ depending on the data
type: Integer or real number.

TAN

Tangent

TAN (MF

− );

TAN (45.0) ;

Obtains the tangent of real number data.
Only a real number type register can be designated.

ASN

Arc Sine

ASN (MF

− );

ASN (90.0) ;

Obtains the arc sine of the real number data.
Only a real number type register can be designated.

ACS

Arc Cosine

ACS (MF

− );

ACS (90.0) ;

Obtains the arc cosine of real number data.
Only a real number type register can be designated.

ATN

Arc Tangent

ATN (MW

− );

ATN (45) ;

Obtains the arc tangent of integer or real number
data.
The specifications differ depending on the data
type: Integer or real number.

SQT

Square Root

SQT (MW

− );

SQT (100) ;

Obtains the root of integer or real number data.
The specifications differ depending on the data
type: Integer or real number.

BIN

BCD-to-

Binary

BIN (MW

− );

Converts BCD data to binary data.

BCD

Binary-to-

BCD

BCD (MW

− );

Converts binary data to BCD data.

S {   }

Set Bit

S {MB

− } = MB

− & MB

− ;

If the logical operation result is true, the desig-
nated bit turns ON.
The designated bit does not turn OFF even if the
logical operation result is false.

R {   }

Reset Bit

R {MB

− } = MB

− & MB

− ;

If the logical operation result is true, the desig-
nated bit turns OFF. The designated bit does not
turn ON even if the logical operation result is
false.

PON

Rising Pulse

MB

− = PON (MB

− MB

− );

or
IF PON (MB

− MB

− ) == 1;

;

IEND;

The bit output turns ON for one scan when the bit
input status changes from OFF to ON.

NON

Falling Pulse

MB

− = NON (MB

− MB

− );

or
IF NON (MB

− MB

− ) == 1;

;

IEND;

The bit output turns ON for one scan when the bit
input status changes from ON to OFF.

TON

ON-Delay

Timer

MB

− = MB

− & TON (

− MB

− );

Counts the period of time when the bit input is
ON.
The bit output turns ON when the counted value is
equal to the set value.
Counting unit: 10 ms.

TOF

OFF-Delay

Timer

MB

− = MB

− & TOF (

− MB

− );

Counts the period of time when the bit input is
OFF.
The bit output turns OFF when the counted value
is equal to the set value.
Counting unit: 10 ms.