8 Command Reference

8.1.3 Acceleration Time Change (ACC)

8-16

(5) Supplemental Information on ACC Command

(a) Related Motion Parameters

ACC changes the acceleration time of the following motion setting parameter.

The acceleration time can be changed by directly changing the setting of the motion setting parameter
OL

36 (Straight line acceleration time constant) instead of executing an ACC command. Refer to the fol-

lowing table for details on how to directly change the acceleration time setting.

Motion and setting procedure of acceleration time for positioning related commands are as follows.

* The built-in SVB and SVB-01 modules have a function that can automatically write the setting of motion setting

parameter OL

36 (Straight line acceleration/acceleration time constant) into the SERVOPACK parameters.

When this automatic writing function is enabled, you do not need to use bit 10 (ACC: Change acceleration time)
of motion setting parameter OW

08.

For the automatic writing function, refer to

11.6 Parameters That Are Automatically Updated in Machine Controller

MP2000 Series Built-in SVB/SVB-01 Motion Module User’s Manual (manual number: SIEPC88070033).

(b) Setting Acceleration Time and Deceleration Time

With the following combination of motion module and SERVOPACK model, the acceleration time and
deceleration time cannot be set individually. If you set the acceleration time, the deceleration time will be
automatically set. With SERVOPACK models other than those listed below, the acceleration times and decel-
eration times can be set individually using ACC and DCC commands.

Parameter Name

Register No.

Description

Straight Line Acceleration/
Acceleration Time Constant

OL

36

Sets the linear acceleration rate or linear acceleration time constant.

Motion

Module

Motion

Setting Procedure

SVA-01,
PO-01,
SVR

The axis moves according to the accelera-
tion time of motion setting parameter
OL

36 (Straight line acceleration/

acceleration time constant).

Set an acceleration time to motion setting parameter OL

36

(Straight line acceleration/acceleration time constant).

SVB-01,
Built-in
SVB

The axis moves at the acceleration rate of
the SERVOPACK parameter.

Set an acceleration time using motion setting parameter
OL

36. Then, use bit 10 (ACC: Change acceleration time)

of motion setting parameter OW

08 (Motion command) to

write the new acceleration time into the SERVOPACK.

*

Motion

Module

SERVOPACK

Model

Description

SVB-01,
Built-in SVB

SGD-N

• With a built-in SVB or SVB-01 module, the axis moves at the acceleration/decelera-

tion rate of the SERVOPACK parameter.

• SGD-N and SGDB-N SERVOPACKs uses same parameter to set both acceleration

time and deceleration time.

SGDB-N