5 s-curve time constant change (scc), 1) overview, 2) format – Yaskawa MP2000 Series: User's Manual for Motion Programming User Manual

Page 130

Advertising
background image

8.1 Axis Setting Commands

8-23

8

Command Reference

8.1.5 S-curve Time Constant Change (SCC)

(1) Overview

The S-curve Time Constant Change command (SCC) changes the S-curve time constant of each axis for which
an axis move command is executed.
The S-curve time constant is the parameter for the S-curve acceleration/deceleration function that suppresses
mechanical vibration during acceleration/deceleration.
The S-curve time constant for up to 16 axes can be changed at once. The S-curve time constant of any axis
unspecified in the command block is not changed.
The S-curve time constant changed by the SCC command remains until it is reset by the next SCC command.

Fig. 8.11 S-curve Time Constant Change

All motion modules, except the PO-01 module, support ACC, DCC, and SCC commands.
Use of these commands with PO-01 module requires the following combination of Machine Controller and PO-01 module
version numbers.

(2) Format

Motion Programs

Sequence Programs

Applicable

Not applicable

MP2000 Series Version Number

PO-01 Version Number

Ver.2.46 or later

Ver.1.06 or later

Speed (V)

Time (t)

Before S-curve time constant change

Speed (V)

Time (t)

After S-curve time constant change

INFO

. . . ;

Item

Unit

Data That Can Be Used

S-curve time

constant

ms

Directly designated value

Double integer register (indirect designation)

SCC [Logical axis name 1] S-curve time constant [Logical axis name 2] S-curve time constant

Advertising