9 Engineering Tool MPE720

9.6.2 Drive Control Panel Details

9-26

9.6.2 Drive Control Panel Details

a) Program exec registry No.

The program execution registry number of the program for trial run is displayed.
The program execution registry number must be set in the Program execution registry screen dialog box of
the M-EXECUTOR in advance.

b) Program number

The program number for trial run is displayed.
The program number must be set in the Program execution registry screen dialog box of M-EXECUTOR
in advance.

c) START button

Click the START button to start the trial run.

d) PAUSE button

Click the PAUSE button to pause the trial run.

e) STOP button

Click the STOP button to stop the trial run.

f) ALMRST button

Click the ALMRST button to reset the alarm after an alarm has been generated.

g) Trial run status display

The corresponding status indicator LED lights up to indicate the trial run status.

• RUNNING: Lights up when the START button is clicked.
• PAUSING: Lights up when the PAUSE button is clicked.
• STOPPED: Lights up when the STOP button is clicked.
• ALARM: Lights up when a program alarm occurs.
• PRGNOERR: Lights up when a program number error occurs (the program number is outside the

allowable range).

b)
c)
d)
e)
f)

g)

h)

a)