Brocade Network Advisor IP User Manual v12.3.0 User Manual

Page 1286

Advertising
background image

1234

Brocade Network Advisor IP User Manual

53-1003153-01

Policy monitor overview

37

Make sure to configure the host port mapping. (refer to

“Host port mapping overview”

on

page 703)

-

Host adapter discovery with 2.1 or later driver for host to unmanaged fabric connections
(refer to

“Host discovery”

on page 97)

Make sure there are Brocade HBAs on the host.

-

Fabric plus Host adapter discovery with 2.1 or earlier driver (refer to

“Host discovery”

on

page 97)

Make sure there are Brocade HBAs on the host.

-

Fabric plus VM Manager for hosts discovered through vCenter (refer to

“VM Manager

discovery”

on page 108)

Make sure there are Brocade HBAs on the host.

Make sure you discover the associated fabrics.

-

VM Manager plus Host adapter discovery (refer to

“VM Manager discovery”

on page 108)

Make sure there are Brocade HBAs on the host.

Make sure you discover the associated fabrics.

Rule Violation Fix — If the configuration policy manager report shows a violation, the
Administrator can add a host connection to additional fabrics.

Check for connections through two fabrics to each target LUN — This host configuration policy
manager enables you to determine if there are redundant connections between the host group
and the target LUN.

To prevent a single point of failure, the host should have a redundant connection to the target
LUN. Available hosts include both automatic hosts and manual hosts. An automatic host is a
host discovered through Host adapter discovery or VM Manager discovery. A manual host is a
host enclosure manually created through host port mapping in the fabric topology.
Depending on how you discover the hosts, there are recommended configurations you should
complete to avoid inaccuracy:

-

Host adapter discovery (refer to

“Host discovery”

on page 97)

Make sure there are Brocade HBAs (with a 2.1 or later driver) on the host.

-

Fabric plus Host discovery (refer to

“VCS fabric discovery”

on page 43)

Make sure there are Brocade HBAs on the host connected to the fabric.

Make sure to configure the host port mapping (refer to

“Host port mapping overview”

on

page 703).

-

Fabric plus VM Manager discovery (refer to

“VM Manager discovery requirements”

on

page 109)

Make sure there are Brocade HBAs (with a 2.1 or later driver) on the host connected to the
fabric.

-

VM Manager plus Host discovery (refer to

“VM Manager discovery”

on page 108)

Make sure there are Brocade HBAs (with a 2.1 or later driver) on the host.

Make sure you discover the associated fabrics.