Adding a configuration policy manager

37

FIGURE 528

Add Configuration Policy Manager dialog box, Hosts Checks tab

a. Select the Check for redundant connections to attached fabrics check box to determine if

there are at least the minimum number of configured physical connections between the
host and the attached fabric.

The default is 2. For more information about this check and a fix for rule violations, refer to

“Host configuration policy managers”

on page 1233.

b. Enter the minimum number of connections between the host and the attached fabric in

the Minimum Connections field.

The default is 2.

c. Select the Check for connections through two fabrics to each target LUN check box to

determine if there are redundant connections between the host group and the target LUN.

For more information about this check and a fix for rule violations, refer to

“Host

configuration policy managers”

on page 1233.

d. Select the hosts to which you want to apply this policy in the Available Hosts list and click

the right arrow button.

NOTE

You can use the All Host target in the Available Hosts list for future provisioning. Select All
Hosts and click the right arrow button to apply this policy to all discovered hosts.

The selected hosts display in the Selected Hosts list.

9. To set configuration policy managers for the Management application (

Figure 529

), complete

the following steps.