Configuring a switch for FICON operation

22

13. Select the Repository tab to import new firmware files for downloads. Refer to the “Firmware

management” section in

Chapter 14, “SAN Device Configuration”

for more information on

importing firmware.

14. If you are not using virtual fabrics or you do not plan to enable virtual fabrics and only use the

default switch, skip to

step 15

. As an option at this point, you can configure virtual fabrics by

referring to procedures in the following sections under “Configuring Virtual Fabrics” in the

“Virtual Fabrics”

chapter, then return to

step 15

.

“Enabling Virtual Fabrics”

“Creating a logical switch or base switch”

“Assigning ports to a logical switch”

For best practices for configuring virtual fabrics, refer to

“FICON best practices for Virtual

Fabrics”

on page 959.

15. To configure the switch as part of a fabric, follow procedures under

“Configuring a cascaded

FICON fabric”

on page 827, then return to

step 16

.

16. If a name does not display for the switch after configuring the fabric, right click the switch icon

in topology of the SAN tab and select Properties.

The switch Properties dialog box displays.

17. Edit the switch name.

18. Define port fencing parameters for the switch using the following steps (optional):

NOTE

Although this is an optional step, best practice is to configure port fencing.

a. Configure thresholds that you require for the switch using steps under the “Adding

thresholds” in

Chapter 21, “Port Fencing”

.

Following are recommend parameters for the various thresholds:

C3 Discard Frames = 2 per minute.

Invalid Words = 25 per minute.

Invalid CRCs = 3 per minute. Note that it is not uncommon for an ISL to travel through
a path that is more prone to noise than internal data center connections to control
units and channels. Therefore, a slightly higher CRC threshold may be better for E-Port
connections. In most cases the CRC is set to 3.

Link Reset = 2 per minute.

Protocol Error = 2 per minute.

State Change = 7 per minute.

b. Assign a threshold to the switch using steps under “Assigning thresholds” in

Chapter 21,

“Port Fencing”

.

19. Set the zoning policy for the switch by referring to steps under “Enabling or disabling the

default zone for fabrics” in