Banner Information

5

Command Usage

Input strings cannot contain spaces. The banner configure dc-power-info command interprets
spaces as data input boundaries. The use of underscores ( _ ) or other unobtrusive non-letter
characters is suggested for situations where white space is necessary for clarity.

Example

Console(config)#banner configure dc-power-info floor 3 row 15 rack 24

electrical-circuit 48v-id_3.15.24.2

Console(config)#

banner configure department

This command is used to configure the department information displayed in the banner. Use the no
form to restore the default setting.

Syntax

banner configure department dept-name

no banner configure department

dept-name - The name of the department. (Maximum length: 32 characters)

Default Setting

None

Command Mode

Global Configuration

Command Usage

Input strings cannot contain spaces. The banner configure department command interprets
spaces as data input boundaries. The use of underscores ( _ ) or other unobtrusive non-letter
characters is suggested for situations where white space is necessary for clarity.

Example

Console(config)#banner configure department R&D

Console(config)#

banner configure equipment-info

This command is used to configure the equipment information displayed in the banner. Use the no
form to restore the default setting.

Syntax

banner configure equipment-info manufacturer-id mfr-id floor floor-id row row-id rack rack-id

shelf-rack sr-id manufacturer mfr-name

no banner configure equipment-info [floor | manufacturer | manufacturer-id | rack | row |

shelf-rack]

mfr-id - The name of the device model number.

floor-id - The floor number.

Advertising