Ethernet cfm cc enable – Brocade Communications Systems Brocate Ethernet Access Switch 6910 User Manual

Page 593

Advertising
background image

Brocade 6910 Ethernet Access Switch Configuration Guide

543

53-1002581-01

CFM Commands

25

ethernet cfm cc enable

This command enables the transmission of continuity check messages (CCMs) within a specified
maintenance association. Use the no form to disable the transmission of these messages.

Syntax

[no] ethernet cfm cc enable md domain-name ma ma-name

domain-name – Domain name. (Range: 1-43 alphanumeric characters)

ma-name – Maintenance association name. (Range: 1-43 alphanumeric characters,
maximum length is 44 minus the length of the domain name)

Default Setting

Disabled

Command Mode

Global Configuration

Command Usage

CCMs are multicast periodically by a MEP in order to discover other MEPs in the same MA, and
to assure connectivity to all other MEPs/MIPs in the MA.

Each CCM received is checked to verify that the MEP identifier field sent in the message does
not match its own MEPID, which would indicate a duplicate MEP or network loop. If these error
types are not found, the CCM is stored in the MEP’s local database until aged out.

If a maintenance point fails to receive three consecutive CCMs from any other MEP in the same
MA, a connectivity failure is registered.

If a maintenance point receives a CCM with an invalid MEPID or MA level or an MA level lower
than its own, a failure is registered which indicates a configuration error or cross-connect error
(i.e., overlapping MAs).

Example

This example enables continuity check messages for the specified maintenance association.

Console(config)#ethernet cfm cc enable md voip ma rd

Console(config)#

Advertising