Brocade 6910 Ethernet Access Switch Configuration Guide

275

53-1002581-01

Interface Commands

12

transceiver-threshold voltage

This command sends a trap when the transceiver voltage falls outside the specified thresholds.

Syntax

transceiver-threshold voltage {high-alarm | high-warning | low-alarm | low-warning}

threshold-value

high-alarm – Sends an alarm message when the high voltage threshold is crossed.

high-warning – Sends a warning message when the high voltage threshold is crossed.

low-alarm – Sends an alarm message when the low voltage threshold is crossed.

low-warning – Sends a warning message when the low voltage threshold is crossed.

threshold-value – The threshold of the transceiver voltage. (Range: 100-25500 in units of
0.01 Volt)

Default Setting

None

Command Mode

Interface Configuration (Ethernet)

Command Usage

Refer to the Command Usage section under the

transceiver-threshold current

command for

more information on configuring transceiver thresholds.

Trap messages configured by this command are sent to any management station configured by
the

snmp-server host

command.

Example

The following example sets alarm thresholds for the transceiver voltage at port 1.

Console(config)interface ethernet 1/1

Console(config-if)#transceiver-threshold voltage low-alarm 4

Console(config-if)#transceiver-threshold voltage high-alarm 2

Console#