background image

650

Brocade 6910 Ethernet Access Switch Configuration Guide

53-1002581-01

Displaying Hardware/Software Versions

32

Interface

To configure general system information:

1. Click System, General.

2. Specify the system name, location, and contact information for the system administrator.

3. Click Apply.

FIGURE 8

System Information

Displaying Hardware/Software Versions

Use the System > Switch page to display hardware/firmware version numbers for the main board
and management software, as well as the power status of the system.

CLI References

•

"System Management Commands" on page 47

Parameters

The following parameters are displayed:

Main Board Information

•

Serial Number – The serial number of the switch.

•

Number of Ports – Number of built-in ports.

•

Hardware Version – Hardware version of the main board.

•

Internal Power Status – Displays the status of the internal power supply.

Management Software Information

•

Role – Shows that this switch is operating as Master or Slave.

•

EPLD Version – Version number of EEPROM Programmable Logic Device.

•

Loader Version – Version number of loader code.

•

Operation Code Version – Version number of runtime code.

•

Thermal Detector – The first detector is located between the physical layer ASICs on the main
board. The second and third detector are located on right and left side of daughter board.

•

Temperature – Temperature at specified thermal detection point.