Brocade 6910 Ethernet Access Switch Configuration Guide

53-1002581-01

CFM Commands

25

clear ethernet cfm ais mpid

Clears AIS defect information for the specified MEP

PE

show ethernet cfm
configuration

Displays CFM configuration settings, including global settings, SNMP
traps, and interface settings

PE

show ethernet cfm md

Displays configured maintenance domains

PE

show ethernet cfm ma

Displays configured maintenance associations

PE

show ethernet cfm
maintenance-points local

Displays maintenance points configured on this device

PE

show ethernet cfm
maintenance-points local
detail mep

Displays detailed CFM information about a specified local MEP in the
continuity check database

PE

show ethernet cfm
maintenance-points remote
detail

Displays detailed CFM information about a specified remote MEP in
the continuity check database

PE

Continuity Check Operations

ethernet cfm cc ma interval

Sets the transmission delay between continuity check messages

GC

ethernet cfm cc enable

Enables transmission of continuity check messages within a specified
maintenance association

GC

snmp-server enable traps
ethernet cfm cc

Enables SNMP traps for CFM continuity check events

GC

mep archive-hold-time

Sets the time that data from a missing MEP is kept in the continuity
check database before being purged

CFM

clear ethernet cfm
maintenance-points remote

Clears the contents of the continuity check database

PE

clear ethernet cfm errors

Clears continuity check errors logged for the specified maintenance
domain and maintenance level

PE

show ethernet cfm errors

Displays CFM continuity check errors logged on this device

PE

Cross Check Operations

ethernet cfm mep
crosscheck start-delay

Sets the maximum delay that a device waits for remote MEPs to come
up before starting the cross-check operation

GC

snmp-server enable traps
ethernet cfm crosscheck

Enables SNMP traps for CFM continuity check events, in relation to the
cross-check operations between statically configured MEPs and those
learned via continuity check messages

GC

mep crosscheck mpid

Statically defines a remote MEP in a maintenance association

CFM

ethernet cfm mep
crosscheck

Enables cross-checking between the list of configured remote MEPs
within a maintenance association and MEPs learned through
continuity check messages

PE

show ethernet cfm
maintenance-points remote
crosscheck

Displays information about remote maintenance points configured
statically in a cross-check list

PE

Link Trace Operations

ethernet cfm linktrace
cache

Enables caching of CFM data learned through link trace messages

GC

TABLE 124

CFM Commands (Continued)

Command

Function

Mode