Automatic Traffic Control Commands

16

Usage Guidelines

ATC includes storm control for broadcast or multicast traffic. The control response for either of
these traffic types is the same, as shown in the following diagrams.

FIGURE 1

Storm Control by Limiting the Traffic Rate

The key elements of this diagram are described below:

Alarm Fire Threshold – The highest acceptable traffic rate. When ingress traffic exceeds the
threshold, ATC sends a Storm Alarm Fire Trap and logs it.

When traffic exceeds the alarm fire threshold and the apply timer expires, a traffic control
response is applied, and a Traffic Control Apply Trap is sent and logged.

Alarm Clear Threshold – The lower threshold beneath which a control response can be
automatically terminated after the release timer expires. When ingress traffic falls below this
threshold, ATC sends a Storm Alarm Clear Trap and logs it.

When traffic falls below the alarm clear threshold after the release timer expires, traffic control
(for rate limiting) will be stopped and a Traffic Control Release Trap sent and logged. Note that
if the control action has shut down a port, it can only be manually re-enabled using the

auto-traffic-control control-release

command).

The traffic control response of rate limiting can be released automatically or manually. The
control response of shutting down a port can only be released manually.

ATC Display Commands

show auto-traffic-control

Shows global configuration settings for automatic storm control

PE

show auto-traffic-control
interface

Shows interface configuration settings and storm control status for
the specified port

PE

* Enabling automatic storm control on a port will disable hardware-level storm control on the same port if configured by the

switchport packet-rate

command.

TABLE 74

ATC Commands (Continued)

Command

Function

Mode

Storm Alarm

Fire TRAP

Alarm Fire
Threshold
(1~255kpps)

AlarmClear
Threshold
(1~255kpps)

Traffic

[kpps]

Time

Traffic without storm control

Traffic with storm control

Apply Timer
expired

(0~300sec)

Auto Storm Control

Release Timer
expired
(0~300sec)

Storm Alarm

Fire TRAP

StromAlarm

ClearTRAP

TrafficControl
Apply Trap

StromAlarm

ClearTRAP

TrafficControl
Release Trap

Storm Alarm

Fire TRAP

Alarm Fire
Threshold
(1~255kpps)

AlarmClear
Threshold
(1~255kpps)

Traffic

[kpps]

Time

Traffic without storm control

Traffic with storm control

Apply Timer
expired

(0~300sec)

Auto Storm Control

Release Timer
expired
(0~300sec)

Storm Alarm

Fire TRAP

StromAlarm

ClearTRAP

TrafficControl
Apply Trap

StromAlarm

ClearTRAP

TrafficControl
Release Trap

Advertising